- 1. Counter - Clock/measure/beat counter mode. PARAM selects one of 32 different counting patterns. The patterns are arranged in eight groups of four, each group of four has a different time signature. Starting from 2 through to 9. Use this mode to do boring predictable 2/4,3/4, 4/4 stuff OR go wild and spice up sequences, extend notes and clock sequencers in odd but super cool ways.
- 2. Divider - 4 pattern outputs, each is assigned a different clock division. PARAM selects 1 of 32 different clock divisions for each output. Use this with a logic AND/OR gate to spice up rhythms or sequences or any trigger/gate related function really!
- 3. Arrhythmia - Mathematically (and deliberately) messed up euclidean rhythms - each of the 4 outputs on a cycle that never quite align but still seem to work. There are 32 of them - PARAM selects a patch from 1 to 32. Each of the 32 patterns has an alternate pattern that is activated when a RESET signal is received. A subsequent RESET signal will revert back to the original pattern. The 32nd pattern has a special twist - each time a RESET is received a new rhythmically awkward pattern will be generated.
- 4. Basic Drum Patterns - Some times you just need a basic drum pattern to noodle or perform over. Pathogen delivers! 32 x basic patterns, each 16 steps in length. PARAM selects which rhythm and RESET input will do what you would expect (it goes back to the start of the pattern duh!).
- 5. Random (1 of 4) - A random pattern of 1 to 32 steps where ONLY one of the four outputs can be active at a time. PARAM sets the number of steps from 1 to 32. Each time a RESET is received a whole new random sequence is generated.
- 6. Random (4 of 4) - Kinda like the previous algorithm except any of the outputs can be active at a time. PARAM sets the number of steps from 1 to 32. Each time a RESET is received a whole new random sequence is generated.
- 7. Probability (1 of 4) - Probability based 1 of 4 pattern. So what does this actually mean?? The PARAM control adjusts the probability from 0% to 100%. On each step a random number is generated. If the random number is greater than the probability, then a new pattern is generated where only ONE of the four outputs is active.
- 8. Probability (4 of 4) - Again, just like the previous algorithm EXCEPT any of the four outputs can be active.
Pathogen Full DIY Kit
Description
Pathogen is comprised of two separate tempo synchronized sections. The first section is a burst generator for trigger signals, with length, "physics" based density and its own clock divider/multiplier.
The second section is a four output pattern generator with eight modes.
The second section is a four output pattern generator with eight modes.
Features
$195.00